  DET4TC2 & det4tcr2 digital ground testers description megger det4 family of ground testing instr uments offers a comprehensive solution to your ground stak e and soil resistivity testing needs. the basic kit option comprises, the instr ument, test leads, stak es, batteries and calibration cer - tificate are delivered in a tough car ry case which has space to accommodate all the instrument accessories - everything you need to start testing in one kit. the DET4TC2 and det4tcr2 are designed for extended temperature range use with an ip54 rated enclosure making them genuinely outdoor instruments. the instrument provides all the functions required for ground system testing: variable frequency 2 pole, 3 pole, 4 pole, attached rod technique (art), stakeless, leakage current and ground noise voltage measurement. the instr ument is easy to use with a large rotar y selector switch and one-press test button, both of which permit operation with gloved hands. unlike some instruments, the design negates the need for a shorting link when making two pole measurements. there are no hidden functions with the instrument: clearly labelled auxiliary controls are used to select the test frequency (94 hz, 105 hz, 111 hz and 128 hz), output voltage (50 v or 25 v where local standards apply) and to switch the backlight on or off. the optional iclamp augments the traditional fall-of- potential measurement method with art (attached rod technique) which allows electrode testing without disconnection and also leakage cur rent measurements down to 1 ma. a second optional clamp, the vclamp, enables tr ue stak eless measurements to be made in situations where driving stakes is not practical. the clear , easy-to-read display provides excellent contrast and viewing angle making the instrument ideally suited to outdoor use. the display is backlit, extending the operational environment of the instrument to cable cellars and other dark locations. the instrument offers a wide measurement range of 0.01 to 200 k , ground noise voltage measurement from 1 v to 100 v and ground cur rent from 1 ma to 20 a. accurate results can be obtained in electrically noisy environments since the instrument is capable of rejecting noise voltages of 40 v peak to peak and the user can select different test frequencies to minimise the effect of interference. the DET4TC2 digital ground tester is powered from 8 aa batteries which are widely available and deliver excellent testing time. the det4tcr2 is powered from rechargeable aa cells. the battery charger is built in and the instrument is supplied with an ac/dc adaptor. for both instruments, the battery status is display using a bar-graph. the megger ground testers comply with stringent safety standards and are rated to 100 v cat iv. they also have selectable 25 v or 50 v output for compliance with iec 61557-5. n ip54 rated n 2, 3 and 4 point testing n attached rod technique (art) n stakeless measurements n user selectable test frequency n dry cell or rechargeable versions n user selectable output voltage n simple one button operation n robust carry case n backlit display n delivered with calibration certificate DET4TC2 & det4tcr2 digital ground testers
d et4tc2 & det4tcr2 digital ground testers specifications ingress protection ip54 c stake, p stake and noise check automatic noise rejection 40 v pk to pk 2-wire, 3-wire, 4-wire test yes, no shorting links required no disconnect testing (art) yes, with iclamp stakeless measurement yes, with iclamp and vclamp instrument output voltage: ?5 v or ?0 v at 94 hz, 105 hz, 111 hz and 128 hz current: 4.5 ma or 0.45 ma or 0.045 ma gr ound curr ent range with clamp 0.5 ma to 19.9 a ground current accuracy 5% 3 digits ground voltage range 0 to 100 v ac gr ound voltage accuracy 2% 2 v resistance range 0.01 to 200 k resistance accuracy 2p measurements: 2% ? digits 3p measurements: 2% ? digits 4p measurements: 2% ? digits art measurements: 5% ? digits stakeless measurements: 7% ? digits maximum probe resistance rp limit: 200 k (50 v output voltage) rc limit: 200 k (50 v output voltage) limits reduced to 100 k for 25 v output voltage limits reduced to 5 k for 0.01 resolution display 3 1 M 2 digit high contrast liquid crystal, backlit battery type DET4TC2: 8 off aa (lr6) cells det4tcr2: 8 off aa (lr6) nimh rechargeable cells operating temperatur e range -15 to +55c / 5 to 131f storage temperature range -40c to +70 / --0?to 158f safety complies with the requirements of iec61010-1 100v cat iv between terminal pairs. emc in accordance with iec61326-1 standards compliance complies with the requirements of kema k85b complies with the following parts of en61557, lectrical safety in low voltage distribution systems up to 1000 v a.c. and 1500 v d.c. - equipment for testing, measuring or monitoring of protective measures part 1 - general requirements part 5 - resistance to earth dimensions 203 mm x 148 mm x 78 mm (8in x 5.8in x 3in) weight 1kg (2.2lb)
DET4TC2 & det4tcr2 digital ground testers o rdering information item order code. DET4TC2 basic kit 1000-345 det4tcr2 basic kit (rechargeable) 1000-346 asic kit?ncluded accessories hard carry case stake and wire kit (15m, 10m, 10m, 3m) external ac/dc charger (det4tcr2 only) DET4TC2 + adaptors 1000-402 det4tcr2 + adaptors (rechargeable) 1000-403 adaptorsincluded accessories hard carry case right angle terminal adaptors (to connect bare wires to terminals) external ac/dc charger (det4tcr2 only) kitted options for ar t and stakeless testing DET4TC2 + clamps 1000-365 det4tcr2 + clamps (rechargeable) 1000-366 clamps?ncluded accessories har d car r y case stake and wire kit (15m, 10m, 10m, 3m) iclamp (for ar t testing) vclamp (adds stakeless testing) field calibration check for instrument and clamps right angle ter minal adaptors (to connect bar e wir es to ter minals) external ac/dc charger (det4tcr2 only) pr ofessional kitted options for ar t and stakeless testing DET4TC2 + kit 1000-404 det4tcr2 + kit (r echargeable) 1000-405 kit?ncluded accessories hard carry case stake and wire kit (15m, 10m, 10m, 3m) iclamp (for art testing) vclamp (adds stakeless testing) field calibration check for instrument and clamps right angle terminal adaptors (to connect bare wires to terminals) external ac/dc charger (det4tcr2 only) separate professional ground testing kit (2 x 50m, 2 x 30m, 4 auger stakes, tape measure, in hard carry case item order code. accessories replacement hard carry case 5410-429 replacement calibration check pcb (two-clamp measurements) 6220-831 replacement ground test stakes (x2) for included kit (200mm, 8mm dia) 6220-804 replacement ground test leads (x4) for included kit (15m, 10m, 10m, 3m) 6220-806 replacement auger stake for professional kit 6220-839 replacement cable reel (50m, red cable) for professional kit 1000-349 replacement cable reel (50m, black cable) for professional kit 1000-350 replacement cable reel (30m, green cable) for pr ofessional kit 1000-362 replacement cable r eel (30m, yellow cable) for professional kit 1000-361 replacement exter nal ac/dc adaptor (det4tcr2 only) 6280-370 current clamp and connecting lead iclamp calibration check box (25 ohm) 6220-824 right angle ter minal adaptor set 6220-803 black crocodile clip (1) 6220-850 pr ofessional gr oung testing kit (2 x 50m, 2 x 30, 4 auger stakes, tape measur e, in har d carry case 6320-245 vehicle 12 v socket charger (det4tcr2 only) 6220-375 etting down to ear th megger guide to ear th gr ound testing 21500-072 uk ar chclif fe road dover ct17 9en england t +44 (0) 1304 502101 f +44 (0) 1304 207342 e uksales@megger.com united states 4271 br onze w ay dallas tx 75237-1088 usa t 800 723 2861 (usa only) t +1 214 333 3201 f +1 214 331 7399 e ussales@megger.com other technical sales offices norristown usa, sydney australia, toronto canada, trappes france, kingdom of bahrain, mumbai india, johannesburg south africa, conjur e thailand and t?by sweden register ed to iso 9001:2000 cer t. no. q 09290 registered to iso 14001-1996 cert. no. ems 61597 DET4TC2_4tcr2_ds_en_v04 www.megger.com megger is a registered trademark


▲Up To Search▲   

 
Price & Availability of DET4TC2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X